Honeywell Air Cleaner F112C User Manual

F112A,C; F113A,C  
Portable Air Cleaners  
OWNER’S GUIDE  
The Honeywell Trademark is used under license from Honeywell  
Intellectual Properties, Inc. by Air-Pure Systems.  
Honeywell International Inc. makes no representations or warranties  
with respect to this product  
69-1506-4  
 
OPERATING YOUR AIR CLEANER  
IMPORTANT  
If you have purchased an F112C or an F113C model, you will need to open  
the air cleaner and remove the plastic packaging on the CPZ filter. To  
reassemble the unit, follow the instructions in the Changing Your Filters sec-  
tion.  
Your air cleaner has a power cord that plugs into a 120 Vac electrical outlet. Before  
plugging it in and operating your air cleaner, carefully read all instructions:  
WARNING  
Electrical Shock Hazard.  
Can cause personal injury or equipment damage.  
Do not use air cleaner with any solid-state speed control device.  
Keep foreign objects from blocking the air outlets or intakes, or from entering  
the ventilation or exhaust opening.  
1. Be sure the unit is fully assembled and in an upright position before plugging it  
in.  
2. Do not use the air cleaner outdoors.  
3. Place the air cleaner where the cord and unit are not obstacles to employee and  
customer traffic flow.  
4. Plug the air cleaner polarized plug (one blade is wider than the other) into the  
polarized outlet as designed. Do not attempt to force the plug into the outlet;  
reverse the plug and then if it does not fit into the outlet, contact a qualified elec-  
trician.  
5. If you must use an extension cord, use a heavy duty cord with adequate line  
size.  
6. Do not run the power cord under carpets or rugs.  
7. Keep the cord away from hot surfaces.  
8. Do not use the air cleaner where combustible gases or vapors are present.  
9. Do not expose the air cleaner to rain or operate near water, in a bathroom, or  
other damp location.  
10. Do not sit, stand or place heavy objects on the air cleaner.  
11. Always unplug when not in use and before servicing. To disconnect the air  
cleaner, first turn the speed control to the Off position before removing the plug  
from the outlet.  
12. Do not use the air cleaner with a damaged cord or plug or if the unit was  
dropped, damaged or is malfunctioning.  
3
69-1506-4  
 
MAINTAINING YOUR AIR CLEANER  
CAUTION  
Filter Washing Hazard.  
Washing can damage prefilter, HEPA filter and CPZ canister.  
Do not wash filters.  
Replace filters according to recommended schedule.  
Determining When to Replace Your Filters  
With proper maintenance, your air cleaner is designed to provide years of high-  
efficiency air cleaning. Your air cleaner contains up to three filters, depending on  
model: a carbon prefilter, a HEPA filter and a CPZ canister on some models.  
Replacing Your Prefilter Every Three Months (Quarterly)  
The carbon prefilter captures large airborne particles and helps reduce odors.  
NOTE: Do not operate the air cleaner without the carbon prefilter.  
IMPORTANT:  
Replace the prefilter every three months. If the unit is used in a smoking or  
other persisting unpleasant odor environment, consider purchasing a model  
with a CPZ canister (F112C or F113C). See Table 1 to select filter part num-  
bers.  
Replacing Your Primary HEPA FIlter and CPZ Canister  
The primary HEPA filter and CPZ canister life expectancy depends on the  
concentration of contaminants in the environment where the air cleaner is installed. If  
there are sources of large amounts of particle generation (such as woodworking or  
heavy smoking), the useful life of the prefilter and HEPA filter and CPZ canister may be  
reduced.  
It is recommended changing the HEPA filter and CPZ canister based on operating  
conditions—every three years for light usage, two years for normal usage and one  
year for heavy usage. See Table 1 to select filter part numbers.  
Whenever the combined air resistance of the carbon filter and the HEPA filter and CPZ  
canister becomes excessive due to the amount of contaminants captured, the air  
cleaner begins to audibly pulsate. Instead of a steady stream of air at the outlets, rapid  
puffs of air can be felt.  
When this occurs:  
The carbon prefilter may be clogged and needs replacing.  
The HEPA filter and CPZ canister need replacing if the unit continues to pulsate  
after replacing the carbon prefilter.  
69-1506-4  
4
 
IMPORTANT  
Replace the HEPA filter and CPZ canister every one to three years, depend-  
ing on the environment where the air cleaner is operating.  
Table 1. Selecting Your Replacement Filters.  
Air Cleaner  
Model No.  
Prefilter  
Part No.  
HEPA Filter  
Part No.  
CPZ Canister  
Part No.  
F112A6003  
38002  
21500  
N/A  
F112C6001  
F113A6001  
F113C6009  
38002  
38002  
38002  
28720  
24000  
28600  
32000232  
N/A  
32000231  
Changing Your Filters  
CAUTION  
Electrical Shock Hazard.  
Can cause personal injury or equipment damage.  
Disconnect power before servicing equipment.  
NOTE: No tools are required for disassembly or assembly.  
1. Disassemble the unit as follows (see Fig.1):  
a. Loosen the carrying handle by turning it counterclockwise.  
b. Lift the grille cover from the unit.  
c. Lift the HEPA filter with carbon prefilter from the base.  
d. Remove the CPZ canister, if applicable.  
e. Remove the two velcro strips from the top and bottom of the prefilter and  
remove it from the HEPA filter.  
f. Wrap the new prefilter around the HEPA filter and replace the top and bottom  
velcro strips.  
2. Reassemble the unit as follows:  
a. Place the assembled HEPA filter with carbon prefilter on the base.  
b. Replace the CPZ canister, if applicable.  
c. Replace the grille cover.  
d. Reattach the carrying handle and turn it clockwise until securely tight. Be  
sure not to over-tighten.  
5
69-1506-4  
 
RETRACTABLE  
HANDLE  
GRILLE COVER  
CPZ CANISTER  
(F112C/F113C MODELS ONLY)  
HEPA FILTER  
CARBON PREFILTER  
BASE ASSEMBLY  
(CONTROLS AND MOTOR)  
M14826  
Fig. 1. Air Cleaner components.  
69-1506-4  
6
 
Determining What to Do When Your Air Cleaner Does Not  
Operate  
Check to make sure the power cord is correctly connected in the outlet.  
Test the outlet with another appliance or lamp.  
Check the fuse or circuit breaker; the circuit may be overloaded if other appliances  
are also in use.  
Check to determine if the thermal overload protection device on the air cleaner  
motor has engaged to turn off the air cleaner. If it has, turn the air cleaner motor  
control to Off and wait 30 to 45 minutes before plugging it in and turning to On.  
IMPORTANT  
Do not attempt to repair the unit yourself.  
If none of the above procedures restores operation, consult your distributor or local  
authorized Honeywell Commercial Air Cleaner Distributor where the unit was  
purchased for further information.  
7
69-1506-4  
 
FIVE-YEAR LIMITED WARRANTY  
Air-Pure Systems warrants its air cleaner products to be free from defects in workmanship or  
materials under normal use and service, for a period of five (5) years from the date of purchase  
by the original end-user. If at anytime during the warranty period the product is defective or mal-  
functions, Air-Pure Systems, through the distributor or dealer, from which the product was  
purchased, or through an authorized warranty repair station, shall at Air-Pure Systems option,  
replace or repair the defective product or component.  
This warranty does not cover removal or installation costs. This warranty shall not apply if it is  
shown that the defect or malfunction was caused by damage which occurred during handling or  
shipment, improper electrical connections, improper use of the product or abuse.  
Air-Pure Systems sole responsibility shall be to repair or replace the product within the terms  
stated above. AIR-PURE SYSTEMS SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE  
OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULT-  
ING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF WARRANTY, EXPRESS OR  
IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. (Some states do not allow the exclu-  
sion or limitation of incidental or consequential damages, so this limitation may not apply to you.)  
THE WARRANTIES SET FORTH HEREIN ARE EXCLUSIVE AND AIR-PURE SYTEMS  
EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES, WHETHER WRITTEN OR ORAL,  
IMPLIED OR STATUTORY, INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MER-  
CHANTABILITY, WORKMANSHIP, OR FITNESS FOR A PARTICULAR USE.  
This warranty gives you specific legal rights and you may have other rights which vary from state  
to state.  
How to make a warranty claim or have questions answered:  
Should you have a warranty claim or questions about the warranty policy, contact the distributor  
or dealer from which you purchased the product or the authorized warranty repair stations  
nearest your location.  
NOTE: Do not return any products or parts to the factory without a factory issued “Returned  
Warranty Goods Label” issued by Air-Pure Systems.  
In the event you or other persons, have any questions concerning the use and care of this  
product or this warranty please call or write the factory.  
Air-Pure Systems  
16873 Fish Point Rd. SE  
Prior Lake, MN 55372-1714  
Phone: (800) 998-1919  
Fax: (800) 221-3248  
Air-Pure Systems  
16873 Fish Point Rd. SE  
Prior Lake, MN 55372-1714  
Phone: (800) 998-1919  
Fax: (800) 221-3248  
69-1506-4 Revised 11-07  
 

Graco Swing Sets Open Top Swings User Manual
Grizzly Grinder G4787 User Manual
Hotpoint Cooktop CH50GCIK User Manual
Hotpoint Electric Pressure Cooker EW31 User Manual
Hotpoint Refrigerator FFA52x User Manual
Hotpoint Ventilation Hood HE63 HE73 HE93 User Manual
HP Hewlett Packard Network Cables 04H8095 User Manual
HP Hewlett Packard Stereo System 5614B User Manual
Husqvarna Lawn Mower 47 User Manual
Husqvarna Lawn Mower Accessory 966659501 User Manual